| The
latest development of traffic controllers from SWARCO, the ITC-2
is modular in design and can be configured for all types of intersections.
Using TCP/IP or EC-Trak over Lnet it can be connected directly
to Utopia/Spot or Omnivue control- and monitoring systems.
ITC-2
is available also in a 42V version |
|
Compactly designed SWARCO ITC-2
with 16 signal-groups.
|
| The
controller can be delivered in three different sizes depending on
the number of signal groups required. For normal intersections the
3U rack with 16 signal groups and 32 detectors will be suitable.
For larger intersections, or for covering more than one intersection,
there are versions with 32- and 64 signal groups and 80 detectors. |
|
Components: |
| • |
Built-in
operator panel allowing full control and access to all parameters.
|
| • |
Police
panel can switch signals on/off and to amber flash as well
as full stage control. |
| • |
RS232 terminal interface providing further access to the internal
software for control and debugging. The parameters are password
protected with two security levels. |
| • |
Vehicle
detection system based on inductive loop-detectors with 8
loops per card. Alternatively video detection Autoscope Rackvision
or Atlas card can be installed. |
| • |
Lamp
group cards with triac outputs for 230 or 42 VAC with full
monitoring of voltage and currents on all outputs. Each card
controls two signal groups. |
| • |
Optional
I/O-cards for control of relay input or output. |
| • |
CPU-board
with i386 processor for control and supervision of functions.
The CPU has a real time clock with battery backup. |
|
|
Software
functions: |
| • |
16
traffic plans and 16 traffic situations available with standard
parameters for programming of local and central co-ordination.
Cable-less linking is possible with a GPS clock. |
| • |
One
controller can control up to four independent intersections
in four separate rings. Each ring can have eight primary stages
and unlimited number of secondary stages. The logic is signal
group controlled with a full conflict-matrix between all groups. |
| • |
Traffic
counting with internal detectors with seven-days back-up.
User defined counting interval. |
| • |
Fulfils
Scandinavian LHOVRA-specification. |
| • |
Built-in
bus priority functions. |
| • |
Built-in
advanced programmable control logics enabling the user to
create new functions. |
| • |
For
control and supervision ITC-2 has interfaces to Utopia/Spot,
Omnivue and EC-Trak UTC systems. The controller can send SMS
or E-mails in case of faults. |
| • |
Internal web-interface. |
|
| Safety: |
A
safety CPU guarantees that no hazardous situations occur.
The CPU monitors: |
| • |
All colour- and green/green conflicts |
• |
Min.
and max. lamp load for red, amber and green |
| • |
Signal sequences |
• |
Min. and max. main supply voltage for safe operation |
| • |
All flash periods |
• |
Max.
mains voltage dip before restart |
| • |
For
coordinated signals min and max cycle time |
|
The
safety CPU also includes 4 general purpose inputs and 4 general
purpose outputs |
| • |
Wait
lamp duration |
|
|
|
| Technical
Specifications: |
| • |
Basic
sizes (signal groups)
16,32,48 |
• |
Cabinet
(large)
900 x 1300 x 420 mm |
| • |
Loop
detectors
32, 64, 64 |
• |
Cabinet
(small)
600 x 1300 x 350 mm |
| • |
Video
detectors
Rackvision, Atlas |
• |
Indoor
rack (32 sg) 480 x 400 x 240 mm |
| • |
Voltage
230 VAC ±15% |
• |
Indoor
rack (16 sg) 480 x 135 x 240 mm |
| • |
Ambient
temperature:
-40 +80°C |
• |
Communication
RS 232, Ethernet |
| • |
Load
per output
Max 500 VA |
• |
System
connections: Utopia/Spot, Omnivue, EC-Trak |
| • |
I/O
interfaces
5-48 V, 100 mA |
• |
Certifications
EN-12675, EN-50293, HD-638 S1 |
| • |
Total output: 3,7 kVA |
|
|
|
Swarco
Technology ApS, Klokkestøbervej 21, 5230 Odense M, Denmark
Phone: +45 63 152 200, Fax: +45 63 152 219
e-mail: office@swtech.dk
Copyright © 2006 Swarco Technology ApS |
|
 |
|